Pilot Feasibility Trial of the SafeLM Supraglottic Airway (SGA)

The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Know the risks and potential benefits of clinical studies and talk to your health care provider before participating. Read our disclaimer for details.
 
ClinicalTrials.gov Identifier: NCT05989880
Recruitment Status : Recruiting
First Posted : August 14, 2023
Last Update Posted : May 9, 2024
Sponsor:
Information provided by (Responsible Party):
Lauren Nakazawa, The University of Texas Health Science Center, Houston

Brief Summary:
The purpose of this study is to assess the feasibility of SafeLM as a primary airway device and as a conduit for intubation with and without the use of a bougie

Condition or disease Intervention/treatment Phase
Anesthesia Device: SafeLM as a supraglottic airway device with video capability Device: SafeLM as a supraglottic airway device without video capability Device: SafeLM as a conduit for intubation using an endotracheal tube with video capability Device: SafeLM as a conduit for intubation using a bougie with video capability Not Applicable

Layout table for study information
Study Type : Interventional  (Clinical Trial)
Estimated Enrollment : 60 participants
Allocation: Non-Randomized
Intervention Model: Parallel Assignment
Masking: None (Open Label)
Primary Purpose: Treatment
Official Title: Pilot Feasibility Trial of the SafeLM Supraglottic Airway
Actual Study Start Date : September 19, 2023
Estimated Primary Completion Date : October 2, 2024
Estimated Study Completion Date : December 2, 2024

Arm Intervention/treatment
Experimental: SafeLM as a supraglottic airway device with video capability Device: SafeLM as a supraglottic airway device with video capability
The device will be inserted using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.

Experimental: SafeLM as a supraglottic airway device without video capability Device: SafeLM as a supraglottic airway device without video capability
The device will be blindly inserted without using the video capability and used as a primary airway device for the duration of the surgical procedure. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The position of the device will be confirmed by observing the video image of the glottis on the monitor. The adequacy of ventilation and oxygenation will be assessed by monitoring the patient's end-tidal CO2, pulse oximetry, and clinical signs of effective ventilation. Leak and cuff pressure will be assessed. The video capability of the device will be used to assess the accuracy of placement after the fact. The device will be removed at the end of the surgical procedure or if there are any signs of device malfunction, airway obstruction, or inadequate ventilation.

Experimental: SafeLM as a conduit for intubation using an endotracheal tube with video capability Device: SafeLM as a conduit for intubation using an endotracheal tube with video capability
The device will be inserted, and an endotracheal tube will be advanced through the device under direct visualization using the video capability of the device. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening. The endotracheal tube will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device. The endotracheal tube will be advanced into the trachea, and the position will be confirmed by end-tidal carbon dioxide (EtCO2) detection and chest auscultation. The cuff of the endotracheal tube will be inflated, and mechanical ventilation will be resumed. The SafeLM device will be removed, and the position of the endotracheal tube will be confirmed once again.

Experimental: SafeLM as a conduit for intubation using a bougie with video capability Device: SafeLM as a conduit for intubation using a bougie with video capability
The device will be inserted. Once the device is in place, the cuff will be inflated with the recommended volume of air to ensure an adequate seal around the laryngeal opening.The position of the device will be confirmed by observing the video image of the glottis on the monitor. The video camera on the SafeLM will be turned on to visualize the vocal cords.A standard airway bougie will be introduced through the working channel of the SafeLM under direct visualization using the video capability of the device.The SafeLM device will be removed, and an appropriately sized endotracheal tube will be advanced into the trachea. If a bougie is not able to be inserted into the tracheal under direct visualization, direct insertion of an endotracheal tube into the trachea will be attempted, followed by flexible scope intubation.




Primary Outcome Measures :
  1. Intubation success rate [ Time Frame: at the time of intubation ]
    This is assessed by the ability of the SafeLM to achieve adequate oxygenation and ventilation via the respective procedure once the airway device is in place.


Secondary Outcome Measures :
  1. Number of insertion attempts required to achieve effective oxygenation and ventilation [ Time Frame: at the time of intubation ]
  2. Time to insertion [ Time Frame: at the time of intubation ]
    This is measured by the time from opening the mouth to the time of end tidal CO2 on capnography

  3. Subjective ease of insertion of the airway device [ Time Frame: at the time of intubation ]
  4. Safety of the SafeLM as an SGA [ Time Frame: at the time of intubation ]
    This will be assessed by the number of adverse events such as airway obstruction, aspiration, and hypoxia.

  5. Safety of the SafeLM as a conduit for intubation [ Time Frame: at the time of intubation ]
    This will be assessed by the number of adverse events such as esophageal intubation, bronchial intubation, and hypoxia during the intubation process.



Information from the National Library of Medicine

Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.


Layout table for eligibility information
Ages Eligible for Study:   18 Years and older   (Adult, Older Adult)
Sexes Eligible for Study:   All
Accepts Healthy Volunteers:   No
Criteria

Inclusion Criteria:

  • elective surgery requiring general anesthesia and airway management using a supraglottic airway device or endotracheal intubation

Exclusion Criteria:

  • pregnancy
  • known or suspected difficult airway management
  • history of oropharyngeal or upper airway surgery
  • known or suspected airway or respiratory pathology, such as significant obstructive sleep apnea or chronic obstructive pulmonary disease (COPD)
  • BMI greater than 40 kg/m2
  • unable to undergo intubation via the oral route
  • known or suspected full stomach or other risk factors for aspiration
  • contraindication for the use of neuromuscular blocking agents
  • history of significant gastroesophageal reflux disease (GERD)
  • Vulnerable populations (cognitively impaired persons, prisoners)

Information from the National Library of Medicine

To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.

Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT05989880


Contacts
Layout table for location contacts
Contact: Lauren M Nakazawa, MD 713-500-6775 Lauren.M.Nakazawa@uth.tmc.edu
Contact: Carlos Artime, MD 713-500-6171 Carlos.Artime@uth.tmc.edu

Locations
Layout table for location information
United States, Texas
The University of Texas Health Science Center at Houston Recruiting
Houston, Texas, United States, 77030
Contact: Lauren M Nakazawa, MD    713-500-6775    Lauren.M.Nakazawa@uth.tmc.edu   
Contact: Carlos Artime, MD    713-500-6171    Carlos.Artime@uth.tmc.edu   
Sponsors and Collaborators
The University of Texas Health Science Center, Houston
Investigators
Layout table for investigator information
Principal Investigator: Lauren M Nakazawa, MD The University of Texas Health Science Center, Houston
Layout table for additonal information
Responsible Party: Lauren Nakazawa, Assistant Professor, The University of Texas Health Science Center, Houston
ClinicalTrials.gov Identifier: NCT05989880    
Other Study ID Numbers: HSC-MS-23-0537
First Posted: August 14, 2023    Key Record Dates
Last Update Posted: May 9, 2024
Last Verified: May 2024
Individual Participant Data (IPD) Sharing Statement:
Plan to Share IPD: No

Layout table for additional information
Studies a U.S. FDA-regulated Drug Product: No
Studies a U.S. FDA-regulated Device Product: Yes
Product Manufactured in and Exported from the U.S.: No