EUS-guided Versus Percutaneous Ultrasound-guided Biopsy for Parenchymal Liver Disease
The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Listing a study does not mean it has been evaluated by the U.S. Federal Government. Know the risks and potential benefits of clinical studies and talk to your health care provider before participating. Read our disclaimer for details. |
ClinicalTrials.gov Identifier: NCT06047327 |
Recruitment Status :
Not yet recruiting
First Posted : September 21, 2023
Last Update Posted : September 21, 2023
|
- Study Details
- Tabular View
- No Results Posted
- Disclaimer
- How to Read a Study Record
Liver biopsy may be indicated in various clinical scenarios to help diagnose and manage liver diseases. Endoscopic ultrasound (EUS) liver biopsy and percutaneous USG guided liver biopsy are two methods used to obtain liver tissue samples. EUS involves using an endoscope with an ultrasound probe to guide a needle through the stomach wall and into the liver, while percutaneous ultrasound guided biopsy involves inserting a needle directly through the skin and into the liver using ultrasound guidance.
A specimen measuring 15 mm or more and containing 6 to 8 CPTs is generally considered adequate for the histologic diagnosis of diffuse liver disease. However, stricter requirements of specimen length of 20 mm or longer with 11 or more CPTs for reliable grading and staging of chronic viral hepatitis have been recommended. With this study we aim to study in a head-to-head comparison between EUS-guided and percutaneous (PC) liver biopsies, with regards to tissue acquisition adequacy.
Condition or disease | Intervention/treatment | Phase |
---|---|---|
Liver Cirrhosis | Diagnostic Test: EUS guided liver biopsy Diagnostic Test: Percutaneous Liver Biopsy | Not Applicable |
Aim and Objective - EUS-LB with a 19G Franseen needle is non-inferior to PC-LB with a 18G BioPince Needle, with regards to total specimen length and diagnostic adequacy.
Hypothesis - i. EUS-LB with a 19G FNB needle is non-inferior to PC-LB with a 18G full core biopsy needle, with regards to total specimen length and diagnostic adequacy.
ii. There would be lesser procedure related pain and higher patient satisfaction with EUS-LB compared to PC-LB.
Study population:
- Patients > 18 years of age.
- Eligibility for deep sedation with propofol.
- Undergoing liver biopsy for diagnosis/evaluation/staging.
Study design: All consecutive in-patients and out-patients requiring liver biopsy for evaluation of diffuse parenchymal liver disease will be evaluated for inclusion.
Study period: 1 year
- Sample size with justification: The percentage success rate of procurement of adequate liver biopsies (defined by specimen length ≥ 15 mm and ≥ 8 CPTs) was assumed to be 90% with PC-LB based on two recent retrospective studies comparing PC-LB with EUS-LB. These studies used the bigger 16G Biopince needles. (Literature: Bhogal N. Endosc Int Open 2020, 99%; Facciorusso A. Cancers 2021, 100%). With similar criteria for adequacy, the success rates with EUS-LB were assumed to be 85% for non-inferiority comparison, based on recent studies of EUS-LB using 19G Franseen needles. (Literature: Hashimoto R. Dig Dis Sci 2020, 100%; Aggarwal SN. GIE 2021, 97.2%; Nallapeta N. Hepatology 2021, 55.6%)
- With alpha-value of 10%, power of 80%, and non-inferiority margin of 10%, we need to enroll 44 patients in each of PC-LB and EUS-LB arms, for a total sample size of 88 patients. We plan to enroll 90 patients in this trial to account for technical inadequacies.
- Intervention: Patient after screening for all exclusion criteria will be randomized into either EUS guided liver biopsy or USG guided percutaneous biopsy
- Monitoring and assessment: All patients would undergo vital and baseline parameter screening before randomization. Based on randomization they will undergo the liver biopsy procedure. Post procedure all the patients will be closely observed in the recovery area for at least 4 hours after the procedure, VAS for pain will be noted & 4-point patient satisfaction scale will be provided to them. They will be followed up after 72 hours by a phone call or in their rooms if updated to check for any adverse effects.
- Pain will be assessed with a visual analogue scale (VAS) score (minimum score = 0, maximum score = 10).
- Patient satisfaction will be evaluated by using a four-point scale ('Very satisfied', 'Satisfied', 'Less satisfied' and 'Not satisfied at all').
- Statistical Analysis: Descriptive data following a normal distribution will be reported as means (+ standard deviation [SD]), whereas nonparametric data will be reported as median (range). Comparisons between the two needles will be performed with a t test, Wilcoxon rank sum test, or chi-square test as appropriate.
- A Mantel-Haenszel test of trend will be performed to determine whether a linear association existed between EUS-LB sampling and VCTE and CAP results.
- Adverse effects:
AEs will be defined as any deviation from the anticipated intra-procedure and post-procedural course.
Study Type : | Interventional (Clinical Trial) |
Estimated Enrollment : | 90 participants |
Allocation: | Randomized |
Intervention Model: | Parallel Assignment |
Masking: | None (Open Label) |
Primary Purpose: | Diagnostic |
Official Title: | EUS-guided Versus Percutaneous Ultrasound-guided Biopsy for Parenchymal Liver Disease: A Randomized Controlled, Non-inferiority Trial |
Estimated Study Start Date : | September 15, 2023 |
Estimated Primary Completion Date : | August 31, 2024 |
Estimated Study Completion Date : | August 31, 2024 |
Arm | Intervention/treatment |
---|---|
Experimental: EUS Guided Liver Biopsy
Procedure will be done by 19G Franseen needle in EUS guided liver biopsy.
|
Diagnostic Test: EUS guided liver biopsy
Procedure will be performed by 19G Franseen needle. |
Active Comparator: Percutaneous Liver Biopsy
Procedure will be done by 18G BioPince Needle in percutaneous liver biopsy.
|
Diagnostic Test: Percutaneous Liver Biopsy
procedure will be done by 18G BioPince Needle |
- Specimen adequacy defined by total specimen length (TSL) ≥ 15 mm and ≥ 8 complete portal triads (CPTs) [ Time Frame: Day 0 ]
- Post-procedure pain measured on Visual Analogue Scale from (Minimum: 0, Max:10) [ Time Frame: 4 hours ]
- Pre-fix longest intact specimen length. [ Time Frame: 3 days ]
- Pre-fix aggregate specimen length. [ Time Frame: 3 days ]
- Total specimen complete portal tracts (CPTs). [ Time Frame: 3 days ]
- Proportion of specimens >20mm in aggregate length. [ Time Frame: 3 days ]
- Proportion of specimens with >11 CPTs. [ Time Frame: 3 days ]
- Total number of fragments. [ Time Frame: Day 0 ]
- Total Number of fragments >9mm. [ Time Frame: 3 days ]
- Proportion of specimens with a conclusive etiological diagnosis [ Time Frame: 3 days ]
- Proportion of specimens with a conclusive pathological diagnosis [ Time Frame: 3 days ]
- Adverse events after the procedure [ Time Frame: 72 hours ]
Choosing to participate in a study is an important personal decision. Talk with your doctor and family members or friends about deciding to join a study. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. For general information, Learn About Clinical Studies.
Ages Eligible for Study: | 18 Years and older (Adult, Older Adult) |
Sexes Eligible for Study: | All |
Accepts Healthy Volunteers: | No |
Inclusion Criteria:
- Patients > 18 years of age.
- Eligibility for deep sedation with propofol.
- Undergoing liver biopsy for diagnosis/evaluation/staging.
Exclusion Criteria:
- Coagulopathy, defined by platelet count < 70,000/mL and/or INR > 1.7.
- Inability to discontinue anticoagulation or antiplatelet agents for 5 days prior to the procedure.
- Presence of unrelieved biliary obstruction.
- Presence of ascites.
- Suspected or known hepatic malignancy.
- Hypertensive patients with uncontrolled blood pressure. (SBP >150 and/or DBP>100mmHg)
- Medically unfit for sedation.
- Inability to provide informed consent.
- Cannot understand Hindi or English should be excluded since they will not be able to reply objectively to questionnaire.
To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor.
Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT06047327
Contact: Dr Ishank Johri, MD | 01146300000 | ishankjohri@gmail.com |
India | |
Institiute of liver and biliary sciences | |
New Delhi, India, 110070 | |
Contact: Dr Ishank Johri, MD 01146300000 ishankjohri@gmail.com |
Responsible Party: | Institute of Liver and Biliary Sciences, India |
ClinicalTrials.gov Identifier: | NCT06047327 |
Other Study ID Numbers: |
ILBS-EUS-01 |
First Posted: | September 21, 2023 Key Record Dates |
Last Update Posted: | September 21, 2023 |
Last Verified: | September 2023 |
Individual Participant Data (IPD) Sharing Statement: | |
Plan to Share IPD: | No |
Studies a U.S. FDA-regulated Drug Product: | No |
Studies a U.S. FDA-regulated Device Product: | No |
Liver Diseases Liver Cirrhosis Digestive System Diseases Fibrosis |
Pathologic Processes Liver Extracts Hematinics |